Details
Contains past questions from the 1st Class Architectural Construction Management Engineer Examination from 2024 to 2010.
There are no in-app charges and no ads.
Study little by little on your phone or tablet during your commute on the train or bus, or during breaks.
You can immediately check the answer to each question by clicking [Question ⇒ Answer].
The question text is also written on the answer page, making it easy to review the questions.
You can check your level of understanding by taking the "Study Confirmation Test (R6 to H29)", which asks 10 random questions.
The questions are asked in a similar pattern every year, so start studying little by little early.
*The following years are included: 1st Reiwa 6, 1st Reiwa 5, 1st Reiwa 4, 1st Reiwa 3, 2020, 201, 2018, 2017, 2016, 2015, 2014, 2013, 2012, 2011, 2010.
One of the important things to do to obtain a qualification is to go through past exam questions.
By going through past exam questions, you can understand what kind of questions are structured, what kind of questions tend to appear, and your areas of weakness and strength, so you can use past exam questions to plan your exam preparation and exam preparation, such as which areas to focus on and which areas to earn points in.
Find your own study method and study in a planned manner.
●Example Question
1st Reiwa 6 Question [No. 1]
Which of the following is the most inappropriate general description of the indoor environment of rooms in buildings equipped with centrally controlled air conditioning equipment?
The speed of indoor air flow shall be 1.5 m/s or less.
2024 1st stage problem [No. 2]
What is the closest value for the thermal conductivity of a reinforced concrete wall as shown in the figure?
However, the heat transfer coefficient shall be the sum of the radiative and convective heat transfer coefficients.
2024 1st stage problem [No. 3]
Which of the following is the most inappropriate general statement regarding reinforced concrete structures?
When a beam has two circular through holes with a diameter of 1/3 of the beam depth, the center distance between the holes shall be at least twice the average diameter of both holes.
2024 1st stage problem [No. 4]
Which of the following is the most inappropriate statement regarding the ground and foundation structure?
The limit value of consolidation settlement is greater for an independent foundation than for a slab foundation.
2024-1st-Question [No. 5]
When concentrated loads P₁ and P₂ act on point C of the three-hinge rigid frame shown in the figure, which of the following is the correct value of the horizontal reaction force Hв generated at support B?
2024-1st-Question [No. 6]
Which of the following is the most inappropriate general statement about interior materials?
Particleboard is a board made by compression molding using wood materials such as wood wool and cement, and is used as a roof underlayment.
2024-1st-Question [No. 7]
Which of the following is the most inappropriate statement about ventilation?
The amount of natural ventilation caused by the temperature difference between indoors and outdoors is inversely proportional to the difference in height between the inlet and outlet, assuming other conditions are the same.
2024-1st-Question [No. 8]
Which of the following is the most inappropriate statement about sound?
When the distance from a point sound source is doubled, the sound pressure level decreases by 3 dB.
2024-1st-Question [No. 9]
Which of the following is the most inappropriate description of the structural plan for a reinforced concrete building?
Columns should be designed to have a large axial compressive stress to avoid the risk of brittle fracture during an earthquake.
2024-1st-Question [No. 10]
Which of the following is the most inappropriate description of the design of a steel frame structure?
In order to provide a high rotational restraint force to the column base, it should be exposed rather than wrapped in a root.
2024-1st-Question [No. 11]
Which of the following is the correct value of the buckling load for the square steel pipe column shown in the table?
However, as shown in the figure, the supports are fixed at both ends and horizontal movement is restrained.
2024-1st-Question [No. 12]
Which of the following is the correct bending moment diagram when a uniformly distributed load ω acts between AB and AC of the beam shown in the figure?
However, the bending moment should be drawn on the tension side of the material.
2024-1st-Question [No. 13]
Which of the following is the most inappropriate general statement about steel materials?
SN490B and SN490C are rolled steel materials for architectural structures that do not have a stipulated upper limit for carbon equivalent.
2024-1st-Question [No. 14]
Which of the following is the most inappropriate statement about plastering materials?
Dolomite plaster has no viscosity by itself, so it needs to be mixed with glue.
2024-1st-Question [No. 15]
Which of the following is the most inappropriate statement about the performance items stipulated in the Japanese Industrial Standards (JIS) for door sets?
For sliding door sets, torsional strength is stipulated.
2024-1st-Question [No. 16]
Which of the following is the most inappropriate statement about surveying?
Stadia surveying is a method of determining the distance between two points with high accuracy using a level and a staff.
2024-1st-Question [No. 17]
Which of the following statements regarding lightning protection equipment is most inappropriate?
Lightning protection equipment must be installed to protect parts of buildings that are over 15m tall from lightning.
2024-1st-Question [No. 18]
Which of the following statements regarding air conditioning equipment is most inappropriate?
The two-pipe piping method in the fan coil unit system allows simultaneous operation of heating and cooling for each zone, and has excellent control over the indoor environment.
2024-1st-Question [No. 19]
Which of the following statements regarding fire extinguishing equipment is most inappropriate?
Outdoor fire hydrant equipment is a system in which a sprinkler head is installed in a location where firefighting activities are difficult, and fires are extinguished by sending water from a fire truck through a connected water supply outlet on the ground floor.
2024-1st-Question [No. 20]
Which of the following statements regarding common expenses in construction costs is incorrect based on the "Public Building Construction Common Expense Estimation Standards (established by the Ministry of Land, Infrastructure, Transport and Tourism)" The costs of installing facilities such as fire extinguishing equipment and maintaining adjacent objects are included in site management costs.
2024-1st-Question [No. 21]
Which of the following is the most inappropriate statement regarding the plan for the access platform?
The position of the access platform's support pillars was determined with the rationality and safety of the work in mind, with the placement of the construction machinery and vehicles to be used as the top priority.
2024-1st-Question [No. 22]
Which of the following is the most inappropriate statement regarding soil testing?
Consolidation tests can be used to determine the settlement characteristics of sandy soil.
2024-1st-Question [No. 23]
Which of the following is the most inappropriate statement regarding retaining walls using the soil cement column wall construction method?
The coarser the in-situ soil that is mixed and stirred with the cement-based injection liquid, the smaller the uniaxial compressive strength of the soil cement.
2024-1st-Question [No. 24]
Which of the following is the most inappropriate statement regarding the construction of cast-in-place concrete piles?
All intersections between the main reinforcement bars and the tie bars of the reinforcing bar cage were welded.
2024-1st-Question [No. 25]
Which of the following is the most inappropriate statement regarding the joints and fastenings of deformed reinforcing bars?
The length of the lap joint between reinforcing bars of different diameters is calculated based on the diameter of the thicker one.
2024-1st-Question [No. 26]
Which of the following is the most inappropriate statement regarding formwork construction?
The deflection of the plywood sheathing was calculated as the average of the value calculated with simple support and the value calculated with both ends fixed.
2024-1st-Question [No. 27]
Which of the following is the most inappropriate statement regarding the curing of concrete?
However, the class of the planned service life shall be standard.
The moist curing period for concrete made with high-early-strength Portland cement is the same as that for concrete made with ordinary Portland cement.
28th Reiwa 6th Year - 1st - Question
Which of the following is the least appropriate statement regarding the construction of large-area steel frames?
The movable platform method is a method in which the roof steel frame assembled on a movable platform is moved to a designated location along with the platform and connected to a previously constructed frame.
29th Reiwa 6th Year - 1st - Question
Which of the following is the least appropriate statement regarding timber frame construction?
The diameter of the tip hole of the screw part of the lag screw is +2mm the screw diameter.
30th Reiwa 6th Year - 1st - Question
Which of the following is the least appropriate statement regarding construction machinery?
Elevators for long-span construction are equipped with a device that automatically shuts off power if the inclination of the carriage exceeds a gradient of 1/8.
2024-1st-Question [No. 31]
Which of the following is the most inappropriate statement regarding synthetic polymer-based roofing sheet waterproofing?
In the adhesive method for polyvinyl chloride resin-based sheet waterproofing, the corners of the entrance and exit are treated by attaching a molded accessory before attaching the sheet.
2024-1st-Question [No. 32]
Which of the following is the most inappropriate statement regarding long galvanized steel sheet roofing?
The upper and lower seams of the flat roofing boards have the same fold width.
2024-1st-Question [No. 33]
Which of the following is the most inappropriate statement regarding light-gauge steel frame wall substrate?
The upper end of the vertical reinforcement material at the entrance opening of the partition wall is fixed to a runner attached to the light-gauge steel frame ceiling substrate.
2024 1st Question [No. 34]
Which of the following is the most inappropriate description of the finish of waterproof synthetic resin emulsion multi-layer finish coating material (waterproof multi-layer coating material E)?
The base coat of the main material was applied in one coat of 1.7 kg/m2, covering the base.
*We have made every effort to ensure that the points in the app are as accurate as possible, but please note that we cannot guarantee their accuracy.
We are not responsible for any inconvenience or disadvantage caused by using this app.
*The content in the app may be added, updated, changed, or revised without notice.